Skip to main content
Energy Lab
Systems lab

Wind energy systems lab

Inspect the turbine. Change conditions. Follow the energy.

Generating
Loading 3D scene…

Drag to orbit 360° · scroll to zoom · right-drag to pan. Select a component to inspect it.

Interconnection power1.71 MW
Rotor speed9.16 RPM
Effective power coefficientCp 0.482
Accumulated energy0.000 kWh

Rotor

9.16 RPM · 1.88 MW

The blades and hub rotate together, converting wind energy into shaft torque.

Hiding is for visual inspection; it does not remove a component from the simulation.
Power curve · current settings
0.02.55.007142128MWm/s

Uses the current yaw, efficiencies and dispatch limit; the dot shows the operating point.

Experiment power history
0.02.55.000111MWs

Time stops when paused or the page is hidden. History retains the last 180 samples.

Power balance

Wind power across swept area
3.91 MW
Mechanical power
1.88 MW
Generator output
1.78 MW
Total conversion losses
175.8 kW
Overall efficiency · electricity / wind power
43.7 %
Local load supplied by wind
0.0 kW
Demand not covered by wind
0.0 kW
Grid export after local load
1.71 MW
Generator speed
888.1 RPM
Main shaft torque
1965.9 kN·m
Tip-speed ratio λ
7.55
Yaw misalignment
0°

Energy & losses

1.709 MWh · Projection at constant conditions for the selected duration; not a weather forecast.

Drivetrain
0.0 kW
Generator
105.5 kW
Converter
26.7 kW
Transformer
26.3 kW
Cables
17.3 kW

Local load is accounted for after interconnection. Remaining demand is not counted as grid import.

Engineering model & sources

P = ½ ρ A v³ Cp · A = π D² / 4 · E = ∫P dt · Cp ≤ 16/27

Quasi-steady teaching model: an approximate Cp curve calibrated at its peak, cos³ yaw loss and a 1.5 m/s startup ramp above cut-in. Rated power limits generator output before converter, transformer and cable losses. Pitch automatically increases when power is limited. Temperature and pressure determine dry-air density.

The NREL preset uses 5 MW, 126 m diameter, 90 m hub height, 97:1 ratio, 94.4% generator efficiency, peak Cp 0.482 at λ=7.55 and wind limits 3 / 11.4 / 25 m/s. The other presets are illustrative teaching configurations, not manufacturer specifications. Geometry is an engineering representation rather than certified CAD; gears and bearings are illustrative.

Controls update the steady operating state immediately. Inertia, structural loads, turbulence and CFD are not solved. Monitoring pauses when the page is hidden; reduced motion stops visual animation while calculations continue. This lab does not certify or design a physical turbine.

NREL/TP-500-38060 · Definition of a 5-MW Reference Wind Turbine