Explore the dam. Operate each unit. Follow water and energy.

Simulation running
Generating
Generating
Generating
Loading 3D plant…

Drag to orbit · scroll to zoom · select a unit or component to inspect. Display rotation is slowed 1:20.

Total output21.66 MW
Turbine discharge46.06 m³/s
Net head54.66 m
Accumulated energy0.000 MWh

Turbine type changes runner geometry, operating envelope and the estimated efficiency curve.

Hiding and disassembly are for inspection; they do not remove parts from the calculation model.

Live performance analysis

0 s
Power vs time0.02.04.06.18.10 s10 sMW
Simulation time: 0.0 sT1: 7.22 MWT2: 7.22 MWT3: 7.22 MW
Hover or touch to inspect a sample. Last 180 seconds of simulated time.

Water and energy paths

Reservoir65.00 mIntakes and penstocks46.06 m³/sTurbines22.56 MWGenerators21.66 MW
Inflow 48.00 m³/sSpillway discharge 0.00 m³/sOverflow at maximum level 0.00 m³/sStorage change 1.93 m³/s
Penstock loss0.15 MWTurbine loss2.14 MWGenerator loss0.90 MW

Generating-unit comparison

Measurement
StatusGeneratingGeneratingGenerating
Electrical power7.22 MW7.22 MW7.22 MW
Discharge15.35 m³/s15.35 m³/s15.35 m³/s
Water velocity1.91 m/s1.91 m/s1.91 m/s
Net head54.66 m54.66 m54.66 m
Head loss0.34 m0.34 m0.34 m
Rotational speed375.0 RPM375.0 RPM375.0 RPM
Generator frequency50.0 Hz50.0 Hz50.0 Hz
Turbine efficiency91.3 %91.3 %91.3 %
Generator efficiency96.0 %96.0 %96.0 %
Net-head pressure equivalent5.36 bar5.36 bar5.36 bar
Shaft torque191.5 kN·m191.5 kN·m191.5 kN·m
Accumulated energy0.000 MWh0.000 MWh0.000 MWh
Methodology, assumptions and model limits

A fictional educational plant, not data from a real dam. Efficiency curves and envelopes are generic estimates, not certified manufacturer curves.

P = ρgQHnetηtηg · v = Q/A · hloss = (fL/D + K)v²/(2g) · n = 120f/p · dV/dt = Qin − Qturbines − Qspill − Qevap − Qoverflow

Reservoir balance uses constant surface area and steps no longer than one second. Runoff has a first-order lag. The grid and test bench are idealized; water hammer, cavitation and structural stresses are not solved. Displayed pressure is a net-head equivalent, not a sensor-location measurement.

Scene proportions are illustrative. Display rotation is slowed 1:20; RPM and calculations use engineering speed. Editing head resets the experimental water level and does not add generated energy to the record.

All simulation results: Estimated — calculated under the stated assumptions.